ANTT in the NMC OSCE: The Wound Dressing Sequence, Key Parts and the Mistakes That Lose Marks
Plenty of candidates can explain aseptic non-touch technique perfectly, then lose marks in ANTT in the NMC OSCE by touching the wrong thing at the wrong moment. The station rewards order, not theory. This guide walks through the whole wound dressing sequence in the order the NMC uses, points out the checks examiners mark, and names the mistakes that quietly cost marks. It covers the Adult Nursing station throughout, with a note on the field difference later.

Quick answer: ANTT is an Adult Nursing clinical skills station marked against the NMC marking criteria. Clean your hands at each stage, clean the trolley, check equipment is sterile, open the sterile field by its corners, dress the wound without touching key parts.
What is ANTT in the NMC OSCE tests
Aseptic non-touch technique, or ANTT, is one of the 22 clinical skills the NMC lists for Adult Nursing, and it sits among the essential clinical skills every OSCE candidate must perfect. The criteria use a wound dressing as the procedure, so the examiner watches how you keep a sterile field while you clean and dress a wound.
The NMC timing document pairs wound assessment and ANTT in a single 21-minute slot, the longest of the skills stations, ANTT is also a new station for Children's Nursing from 26 October 2026, though this guide covers the Adult Nursing station only. Across both fields, the NMC marking criteria assess infection prevention, safe technique, communication with the patient, and professional behaviour under the NMC Code.
Before the patient: hands, trolley and equipment
The first marks in ANTT in the NMC OSCE are earned before you reach the patient, in how you prepare your hands and your trolley. Work through the preparation in the order the criteria set out.
Clean your hands with alcohol hand rub, then put on disposable gloves and an apron.
Clean the trolley with detergent wipes, working from the farthest point to the nearest.
Remove the gloves and apron, and clean your hands again.
Check that all equipment is present and sterile: packaging undamaged, intact and dry, with sterility indicators present and changed where they apply.
Place everything on the bottom shelf of the trolley.
Good hand hygiene and PPE in the NMC OSCE run through every station, so treat each hand-cleaning point as a marked step. The equipment named in the criteria is a sterile dressing pack, sodium chloride 0.9% for cleaning, alcohol cleaning wipes, a wound dressing, alcohol hand rub, and a disposable apron.
At the bedside: the sterile field and the dressing
Consent comes first: confirm the patient agrees to the procedure, as covered in informed consent in the NMC OSCE. From there, the bedside sequence is where aseptic non-touch technique is really tested.
Take the trolley to the bedside, disturbing the curtains as little as possible, and clean your hands with alcohol hand rub, or with soap and water and paper towels following WHO guidelines. Put on an apron.
Open the outer pack once you have checked it is the right way up, then slide the contents onto the top shelf without touching them, and clean your hands.
Open the sterile field using only the corners of the paper, and tip the other packs gently onto the centre.
Clean the saline with an alcohol wipe for 30 seconds, and let it dry for a further 30 seconds.
Clean your hands, put on sterile gloves, and drape the field.
Dip the gauze in saline, clean the wound in a single stroke without over-cleaning, then apply the new dressing. Do not contaminate the field or the key parts at any point.
Every movement at the bedside is planned so the field stays sterile from the moment it is opened.
Finishing well, and where marks are lost
The close of the station is marked too, so finish as carefully as you started.
Replace the bedcovers and dispose of the waste. Verbalising this step is accepted.
Clean your hands. This may also be verbalised.
Avoid any action that contaminates the sterile field (for example, mixing clean and sterile hands, reaching over the open field, or touching key parts).
Check that the patient is comfortable and can reach the call buzzer.
Act professionally throughout, in line with the NMC Code.
Most marks lost in ANTT in the NMC OSCE are lost in small, avoidable slips, each tied to a point in the criteria. The common mistakes to avoid in the OSCE include skipping a hand-cleaning point, not checking the packaging, leaving the saline un-wiped, touching the contents of the pack, reaching over the open field, and over-cleaning the wound. Because the station is timed, OSCE time management tips matter: practise saying each step aloud so you keep both the sequence and the clock.
Frequently asked questions
Is ANTT the same as the wound assessment station?
No. Aseptic non-touch technique and wound assessment have separate sets of marking criteria, though the NMC timing document pairs them in one slot. Confirm with your test centre how the station is run on the day.
Can I say the clean-up steps instead of doing them?
For some steps, yes. The NMC criteria accept verbalisation for disposing of the waste and for the final hand clean. The earlier hand-cleaning and technique steps still have to be performed.
Why do I wipe the saline?
The criteria require you to clean the saline with an alcohol wipe for 30 seconds, then allow 30 seconds for it to dry. It is a marked step in ANTT in the NMC OSCE, not an optional one.
The sequence is the mark
ANTT in the NMC OSCE is not a test of what you know about asepsis. It is a sequence, and the sequence is the mark. Learn the order, clean your hands at every point, protect the field, and the aseptic non-touch technique looks after itself. Practise it in a mock OSCE circuit at Envertiz Academy, with an examiner who watches your hands. Book OSCE training.
Disclaimer
This page is for general guidance only and does not replace the official NMC OSCE marking criteria. Always check the current version of the marking criteria and supporting documents for your examination date on the NMC website.